Patton’s 1052AF is a long-range powered, RS-232 digital modem.
Operating synchronously or asynchronously at full duplex over a
single twisted pair, the Patton 1052AF uses 2B1Q modulation for
superior signal strength even in noisiest environments. RS-232
serial connections can now be extended to distances over 5 miles (8
km) without the use of repeaters! Using ordinary voice-grade wire,
the 1052AF RS-232 Serial Extender provides a cost-effective solution
for dedicated end-to-end connections with synchronous line rates up
to 128 kbps and asynchronous line rates up to 38.4 kbps including
RTS, CTS and DCD modem signals.
The miniature size of the Patton 1052AF allows for a direct
connection to your transmission devices serial port. LEDs are
conveniently located on the side of the Patton 1052AF to provide
at-a-glance status indication of the unit. Additionally, two
8-position dip switches are located at the bottom of the unit to
allow the configuration of various asynchronous or synchronous line
rate settings.
1052/AF/UI
Patton 1052 Manual
Clocking: Internal, external, or receive recover.
Line Coding: 2B1Q conforming to ANSI T1.601 and ETSI ETR-080
standards.
Line Interface: RJ-45; Two-wire twisted-pair using pins 4 &
5; Transformer coupled 1500 VRMS isolation.
Maximum Line Distance for all Data Rates:
• 10.1 miles (16.4 km) on 19 AWG (0.9 mm) wire
• 7.2 miles (11.5 km) on 22 AWG (0.64 mm) wire
• 5.0 (8 km) on 24 AWG (0.5 mm) wire
• 3.4 (5.5 km) on 26 AWG (0.4 mm) wire
Serial Interface: DB-25 Female or DB-9 Female depending on
model ordered.
Serial Data Rates:
• Synchronous: 32, 56, 64, and 128 kbps
• Asynchronous: 0-–38.4 kbps.
LED Indicators: TXD, RXD, Link, NS (no signal), ER (CRC
error).
Power Supplies: External wall-mount power supply with
universal 90–260 VAC input or -12,-24, and -48 VDC input .
Dimensions: 5.18L x 1.69W x 0.75H in. (13.16L x 4.29W x 1.91H
cm)
Weight: 2.01 lbs. (<1.0 kg)
Compliance:
EMC
• FCC Part 15, subpart B, class A (US)
• EMC Directive 89/336/EEC (EU)
• ICES-003 (Canada)
• AZ/NZS 3548 (Australia C-Tick)
• CISPR 22 (International)
Safety
• UL 60950/CAN-CSA-C22.2 60950 (Safety—US/Canada)
• EN 60950 (Safety—Europe/International)
Environment:
• Operating temperature: 32–122°F (0–50°C)
• Humidity: 5–95% non-condensing
• Altitude: 0–15,000 feet (0–4,572 meters) |